Research – Adverse effects of bidet use

‹ PrevPage 1 of 19 · Source p. 9Next ›
Comments

DOCUMENT 2 FOI 25/26-0555

Research – Adverse effects of bidet use

Does habitual bidet toilet use lead to an increase in adverse health concerns (e.g. urological infections, haemorrhoids, bacterial vaginitis, and aggravation of vaginal microflora)? Does this differ between biological sexes? Brief Is there a significant increase in adverse health concerns from bidet use when compared to the general population (e.g. increased likelihood of infection caused by bidet use, or infections are typically present in general population regardless of bidet use)?

Date 16/04/2021

Requester(s) Claire Ms22(1)(a)(ii) - Senior Technical Advisor (TAB)

Researcher Jane S - Research Team Leader (TAB)

Cleared N/A

Please note:

The research and literature reviews collated by our TAB Research Team are not to be shared external to the Branch. These are for internal TAB use only and are intended to assist our advisors with their reasonable and necessary decision-making.

Delegates have access to a wide variety of comprehensive guidance material. If Delegates require further information on access or planning matters they are to call the TAPS line for advice.

The Research Team are unable to ensure that the information listed below provides an accurate & up-to-date snapshot of these matters.

1 Contents

2 Summary …………………………………………………………………………………………………………….. 1 3 Evidence of infections…………………………………………………………………………………………… 2 4 Hygiene status of bidet toilets ……………………………………………………………………………….. 3 5 Association with pre-term birth …………………………………………………………………………….. 3 6 Implementing bidet in aged care or disability settings ……………………………………………… 3 7 References ………………………………………………………………………………………………………… 18

2 Summary

• Literature investigating the adverse effects of bidet use is sparse

Research – Adverse effects of bidet use Page 1 of 19

9 of 112

FOI 25/26-0555

• There is some evidence to suggest that habitual bidet use can cause haemorrhoids, irritated perianal skin, urological infection, vulvar pruritus and bacterial vaginitis o Apart from irritated perianal skin, there are no differences between sexes in infection rate • There is conflicting evidence around the use of bidet use and pre term birth • The implementation of bidets in nursing homes has shown that only 50% of residents and nurses are supportive of bidet use, and that in the majority of cases residents remain unclean and still require toileting assistance (duplication of supports) o One study found that more 28% of bidet users were still required to wipe using toilet paper multiple times • A single study has found that bidet use can assist in reducing toileting time for people with spinal cord injury. However, further studies are required to confirm its effectiveness

3 Evidence of infections

There is some evidence of a positive relationship between haemorrhoids, irritated perianal skin, urological infection, vulvar pruritus and bacterial vaginitis in those considered habitual bidet users [1, 2]. These findings were obtained from moderate quality retrospective surveys that included up to 18,000 participants. It was also found that 28 % of the bidet users wiped off excess water with toilet paper many times [3].

When comparing incidence of non-genital related conditions, Asakura, Nakano [1] found that men more commonly reported subjective symptoms of irritated skin around the anus, which were newly experienced during follow-up than non-habitual users (adjusted risk ratio 1.36 (95% confidence interval 1.06–1.75)). Furthermore, Tsunoda, Takahashi [3] found that men were more commonly affected by an “itch on the anus” because they had faecal leakage more frequently (OR = 3.82) and used a bidet more actively. Other than men being more likely to use a bidet, there were no other gender differences found.

A cross sectional study investigating the possible relevancy of bidet usage to changes in vaginal microflora in 268 women found that normal microflora (Lactobacillus species) was not present in 42.86% of bidet toilet users, compared to 8.77% of non-users. Faecal bacteria were detected in 50 of the 268 cases (18.66%), 46 cases in users (92%) and only 4 cases in non-users (8%). Contamination by other pathogens was 4 to 6 times higher in users than in non-users.

Various case studies have reported that bidet use can cause:

• Anal fissure in the anterior midline

Research – Adverse effects of bidet use Page 2 of 19

10 of 112

FOI 25/26-0555

• Rectal mucosal prolapse syndrome • Scald burn in the perianal region

4 Hygiene status of bidet toilets

A handful of studies have investigated the hygiene status of bidet toilets in public restrooms such as hospitals and Universities. They have found that:

• Pseudomonas aeruginosa is present on about 2% of the toilet seats. P. aeruginosa was found to remain for long durations in biofilms that formed inside warm-water tanks [4] • 86.9% of bidet toilets were found to be contaminated by one or more of the following organisms [5]: o S. aureus, Streptococcus spp o Enterococcus spp o Enterobacteriaceae o non-glucose-fermenting rods (NFR) o other Gram-negative bacteria • The nozzle surface of 87% and 94% of the spray water were found to be contaminated by one or more of the following organisms [6]: o Enterobacteriaceae o Enterococcus spp., o Staphylococcus spp., o non-glucose-fermenting rods, o other Gram-negative bacteria, o other Gram-positive bacteria o Candida spp.

5 Association with pre-term birth

Two studies investigated the bidet use and the association with pre term birth. Both came to differing conclusions. Asakura, Nakano [7] found that normal use of bidet toilets by pregnant women does not pose any clinical health risk with regard to preterm birth. In contrast, Kim, Kim [8] found that chronic bidet toilet use, before and during pregnancy, is associated with abnormal vaginal colonization by gram-negative bacteria (mostly by E coli) and preterm birth.

6 Implementing bidet in aged care or disability settings

Research – Adverse effects of bidet use Page 3 of 19

11 of 112

FOI 25/26-0555

Two studies have investigated the use of bidet toilets in an aged care facility [9] and a spinal cord injury rehabilitation setting [10]. Both of these studies were of low quality with small sample sizes. In the nursing home setting, it was found that only 50% of nurses and residents responded positively to the use of the bidet. Logbook entries revealed that residents were rated as clean only 49% of the time, as slightly dirty 34% of the time, and in the range from somewhat to very dirty for the remaining 17% of the times that they used the wash-and-dry toilets. Therefore, residents still required cleaning following the use of a bidet in most instances.

In those with spinal cord injury time needed for bowel management with the modified bidet device was shorter than that with patients’ usual manner of bowel care (P 0.01). However, residual stools were found in 8 of the 15 patients.

Research – Adverse effects of bidet use Page 4 of 19

12 of 112

Asakura, Nakano [1]

Table 1. Literature Review

Author Aim/ Objective

Evidence of infections

To assess the relationship between bidet toilet use and haemorrhoids or urogenital infections.

Research — Adverse effects of bidet use

FOI 25/26-0555

Methods

Retrospective cross sectional survey

A total of 18,562 people were randonlly selected using a computer programme, to whom a web survey questionnaire was randomly delivered until the number of respondents exceed 10 000. A total of 10 305 individuals were involved in the baseline survey.

1-year and 3-year follow up studies were also conducted.

See methods given in Kiuchi, Asakura [2] below for full details of questionnaire.

13 of 112

Results

Final number of subjects analysed was 7759, giving a follow-up rate of 75.3%.

50.1% of respondents were habitual bidet users. They were more likely to be older, married and wealthier.

In men, more habitual users reported subjective symptoms of irritated skin around the anus, which were newly experienced during follow-up than non- habitual users (adjusted risk ratio 1.36 (95% confidence interval 1.06—1.75)).

Risk ratio based on prevalence of haemorrhoids diagnosed by a physician, subjective symptoms of haemorrhoids and subjective symptoms of irritated perianal skin were significantly higher in habitual users.

Regarding women, no cumulative incidence of outcomes was significantly

associated with bidet toilet use.

Page 5 of 19

Level & Quality of evidence

MODERATE

Large sample, followed over many years. Still low prevalence rates of some conditions to determine an effect.

Large number of respondents eliminated due to inconsistent outcomes.

Table 1. Literature Review

Author

Garg [11] Preliminary report of various cases of anterior fissure-in-ano.

To assess the relationship between habitual bidet toilet use and the incidence of haemorrhoids or urogenital infection.

Kiuchi, Asakura [2]

Research — Adverse effects of bidet use

Aim/Objective

FOI 25/26-0555

Methods

Multiple Case Reports

Prospective web based survey

18,562 people were randomly selected from an online database to receive the questionnaire. A

14 of 112

Results

10 patients of anal fissure in anterior Midline. Two patients presented with acute and eight patients had chronic fissures.

9 men and 1 female patient

Age ranged from 22 to 46 years (median 36 years).

Duration of symptoms ranged from 4 to 7 days in acute cases and 3-8 months (median 5 months) in patients with chronic fissure.

All the patients reported using a bidet-toilet and exposing the perianal region to water stream for a few minutes (range: 1—

5 min).

They were recommended to stop the usage of such a water stream and were advised to use water poured from a container. Conservative treatment was also continued. All except one patient responded well to the treatment and became asymptomatic within 2—3 weeks.

The patient who did not respond to the treatment required an operation.

A total of 7637 subjects were analysed

using single or multiple logistic regression models.

The prevalence odds ratios (ORs) between bidet toilet users and non-users

Page 6 of 19

Level & Quality of evidence VERY LOW

Very brief report. Only descriptions provided.

Considering the rarity of

anterior fissure in men and the ‘cause and effect’ relationship seen in these cases, the water stream of the bidet-toilet being the causative factor of anterior fissure in these cases looks probable.

MODERATE

There is a positive relationship between habitual bidet toilet use and haemorrhoids and urogenital symptoms, except

Table 1. Literature Review

Author

Research — Adverse effects of bidet use

Aim/Objective

FOI 25/26-0555

Methods

total of 10,305 individuals were involved in the baseline survey.

A follow-up web survey was conducted in February 2014. 8255 of the baseline subjects participated again (follow up rate 80.1%).

Survey questions

e Frequency of bidet use: “never used”, “use less than once a week”, “use every day or more than once a week

e Physician diagnosis and subjective symptoms of haemorrhoids, irritated perianal skin, cystitis, pyelonephritis, candida vaginitis, bacterial vaginitis, and vulvar pruritus.

Baseline included questions about

smoking, drinking, fitness, sleeping, showering/bathing, bowel movements, direction of wiping the anus after defecation, menstrual status, sexual activity, academic background, and

past/current histories of diseases.

15 of 112

Results

for haemorrhoids, urological infections, and vulvar pruritus were significantly >1.0

but their incidence ORs were not

significant. The adjusted incidence OR for

bacterial vaginitis symptoms was significant (2.662, 95% confidence interval [Cl] [1.315-5.520]).

No gender differences in relation to prevalence of disease/symptoms. Males more likely to be habitual bidet users.

Page 7 of 19

Level & Quality of evidence

bacterial vaginitis, were due to reverse causation. The incidence of bacterial vaginitis might be caused by bidet toilet use, but the incidence rates were too small to make a definite conclusion, and further studies are needed.

Table 1. Literature Review

Author Aim/Objective

Miura, Kimura [12] Presentation a case of adverse effect after excessive bidet use.

The present study was designed to clarify the possible relevancy of bidet usage to changes in vaginal microflora

Ogino, lino [13]

Research — Adverse effects of bidet use

FOI 25/26-0555

Methods

Case Study

14-year-old boy presented to Hospital because of passage of blood and bloody stools for several months.

The patient’s height was 165 cm, his weight was 45 kg.

No physical abnormal findings of anus/rectum on examination.

Laboratory data were all within reference ranges. Stool culture was negative.

The patient had used a bidet since he was 2 years old. Recently he had been remaining in the bathroom for nearly an hour, using a stream of water at the highest flow setting.

Cross Sectional Study

Participants were recruited in a hospital setting, after attending for complaints relating to vaginal discharge.

Inclusion criteria

16 of 112

Results Level & Quality of evidence

An irregular, elevated, inflamed lesion in VERY LOW

the rectal canal was found. At 10 cm from the anus, a raised, haemorrhagic lesion involving the posterior and right rectal wall was also found.

Single case study.

Rectal mucosal prolapse syndrome

diagnosed and caused by overuse of bidet.

MODERATE 268 women participated 57.6% were habitual bidet users. Cross sectional, uncontrolled study. Relatively small sample to be able to generalise to the greater population.

Normal microflora (Lactobacillus species) was not present in 42.86% of bidet toilet users, compared to 8.77% of non-users.

Page 8 of 19

Table 1. Literature Review

Author Aim/Objective

Presentation a case of scald burn in the perianal region caused by using a bidet

Shulman, Wolf [14]

Research — Adverse effects of bidet use

FOI 25/26-0555

Methods

Women of reproductive age (from 19 to 40 years).

All patients were questioned whether or not they were habitual bidet toilet users. Habitual users were defined as those who use bidet toilets every time at toileting.

An aliquot of cervicovaginal secretion was obtained by a sterilized cotton swab and transferred into culture tubes

Single Case Study

69-year-old female was admitted to the emergency room with a complaint of a pain in the right side of her perineum as a result of hot water from a bidet.

Medical history

Multiple sclerosis diagnosed 2 years prior to her admission and treated with immunoglobulins.

In the last 6 weeks she had received high dose hydrocortisone due to exacerbation of the disease. As

17 of 112

Results Level & Quality of evidence

Faecal bacteria were detected in 50 of the 268 cases (18.66%), 46 cases in users (92%) and only 4 cases in non-users (8%).

Contamination by other pathogens was 4 to 6 times higher in users than in non- users.

Physical examination on arrival revealed a VERY LOW deep third degree burn in the right perianal region measuring less than 1% of | Single case design. Lowest level

total body surface area. on evidence hierarchy.

The burn wound was debrided, its

margins, close to the anal orifice were In the case described, a lack of

sutured. motor coordination in conjunction with sensory

A course of oral antimicrobial treatment problems, caused a deep third was initiated. Conservative treatment was__ degree burn to the right maintained and recovery of the burn perianal region.

occurred within 9 weeks.

No infection or other complications were observed.

Page 9 of 19

Table 1. Literature Review

Author

Tsunoda, Takahashi [3]

Research — Adverse effects of bidet use

Aim/Objective

To investigate the use of bidet toilets among

community dwelling Japanese people and explored the correlates for an itch on the anus.

FOI 25/26-0555 ndis

Methods

part of her disease she suffered from diminished sensation in the lower part of her body.

Cross sectional survey

Convenience sample

Subjects were hospital outpatients and employees or students and employees at two technical colleges

Inclusion criteria Aged >14 years old

Data collection occurred over 2 weeks.

Questionnaire

e Basic demographic information (age and sex)

e General questions on bidet toilet use

© Questions targeting those who use bidet toilets before defecation

© Questions targeting those who use bidet toilets after defecation

18 of 112

Results

4,963 respondents included in the final analysis (3,190 (64 %) women and 1,773 men)

The mean + standard deviation (SD) (range) age of the respondents was 49.6 + 20.2 years

55 % (2,724/4,952) of respondents washed the anus either before or after defecation

83 % (2,253/2,724) of the respondents reported that they had a bidet toilet at home

Men, and older people (aged >50 years) used bidets more actively.

Washing the anus before defecation was associated with constipation (p = 0.005).

28 % (698/2,500) of the respondents

wiped off excess water with toilet paper

many times.

Page 10 of 19

Level & Quality of evidence

MODERATE

Convenience sample, subjective responses

Table 1. Literature Review

Author Aim/Objective

Hygiene status of bidet toilets

To survey the state of residual chlorine and microbial indicators in the spray water of warm-water tanks of bidet toilet seats.

lyo, Asakura [4]

To evaluated the disinfection status and microbial hygiene of the spray water.

To investigate the distribution of antimicrobial-resistant

Kanayama Katsuse, Takahashi [5]

Research — Adverse effects of bidet use

FOI 25/26-0555

Methods

e Questions targeting women who use bidet toilets to wash their genitals

Prospective survey (of bacterial presence)

Residual chlorine and microorganism indicators in the spray water from the warm-water bidet toilet seats were surveyed twice.

Spray water

Spray water was collected directly as it came out of the nozzle, and tap water was used as a control.

Jap water

Approximately 50 mL of tap water was collected for residual chlorine testing in sterilized bottles.

Cross sectional survey

19 of 112

Results

Men might be affected by an itch on the anus, because they had faecal leakage more frequently (OR = 3.82) and used a bidet more actively.

A total of 127 seats were analysed. There were

43 toilet seats for men’s use, 71 for women’s use, and 13 for barrier-free use.

Spray water from the toilet seats had less residual chlorine than their tap water sources. However, the total viable microbial count was below the water- quality standard for tap water.

Heat of the toilet seats’ warm-water tanks caused bacteria in the source tap water to proliferate inside the nozzle pipes and the warm water tanks.

Pseudomonas aeruginosa was detected on about 2% of the toilet seats. P. aeruginosa was found to remain for long durations in biofilms that formed inside warm-water tanks.

254 (86.9%) were found to be contaminated by one or more of the

Page 11 of 19

Level & Quality of evidence

LOW

The existence of P. aeruginosa in spray water, even at low levels is concerning. This has the potential to cause opportunistic infections, especially in immunocompromised individuals.

MODERATE

Table 1. Literature Review

Author Aim/Objective bacteria recovered from bidet toilets at a university-affiliated hospital in Japan.

Tsunoda, Otsuka [6] To evaluate the hygiene

status of bidet toilets

Research — Adverse effects of bidet use

FOI 25/26-0555

Methods

All 292 electronic bidet toilets at a single hospital in Japan were sampled for bacterial contamination.

Swabs were used to sample the warm spray jet from nozzles and toilet seats.

Chromosomal DNA analysis by pulsed-field gel electrophoresis of S. aureus, E. coli and P. aeruginosa isolates were performed.

Prospective survey (of bacterial presence)

A total of 192 tank type bidet toilets were surveyed, of those 103 were in an inpatient ward (48 individual, 55 shared), 34 were in an outpatient clinic, and 55 were in a research building for employees.

Sampling protocol

20 of 112

Results

following organisms: S. aureus, Streptococcus spp., Enterococcus

spp., Enterobacteriaceae, non-glucose- fermenting rods (NFR) and other Gram- negative bacteria.

Enterobacteriaceae were isolated from 84 (28.8%) bidet toilets: E. coli, Enterobacter spp., Klebsiella spp., Citrobacter spp. and other Enterobacteriaceae were found in warm-water nozzles of 38 (13.0%), 22 (7.5%), 13 (4.5%), five (1.7%) and six (2.1%) bidet toilets, respectively.

Of the 192 toilets sampled, the nozzle surface of 167 (87%) and the spray water of 181 (94%) were found to be contaminated by one or more of the following organisms: Enterobacteriaceae

Enterococcus spp., Staphylococcus spp., non-glucose-fermenting rods, other Gram-negative bacteria, other Gram-positive bacteria Candida spp.

Page 12 of 19

Level & Quality of evidence

Single cross sectional study. Unable to confirm ongoing contamination.

Authors conclude that warm- water nozzles of bidet toilets are contaminated with a wide range of bacteria, making them a potential vehicle for infection. In the hospital setting, shared use of bidet toilets must consider the clinical background of patients. Based on these findings, bidet toilets must be part of the risk management programme, and steps should be included for monitoring and disinfection.

LOW

Because the interval of scrubbing the toilets did not have an influence on the contamination of the spray water, self-cleaning mechanisms of spray water should be developed to prevent patients’ possible infections.

Table 1. Literature Review

Author Aim/Objective

Association with pre-term birth/pregnancy

To estimate the association between bidet toilet use and preterm birth, as well as the effect of bidet toilet use on bacterial vaginosis, in pregnant women.

Asakura, Nakano [7]

Research — Adverse effects of bidet use

FOI 25/26-0555

Methods

e Nozzle surface was sampled using swabs before spray water

e Spray water was collected directly as it came out of the nozzle

e Tap water for control specimens was collected from faucets in the restrooms which were surveyed

Retrospective cross sectional survey

All women who gave birth between 2006 and 2010, at Keio University Hospital in Tokyo were invited to participate.

A structured, 6-page questionnaire containing 27 questions about bidet toilet use and other lifestyle factors was sent via mail.

21 of 112

Results

An extended spectrum of B- lactamase producing Escherichia coli was found in one nozzle surface and one spray water. The frequency of colonization from the nozzle surface was significantly greater in the toilets scrubbed every week than that in the units scrubbed every day.

The nozzle surface and the spray water in the bidet toilets were contaminated with a wide range of bacteria.

The final response rate was 64.1%

Of 1,293 women, 63.3% were users of bidet toilets. The incidence of preterm birth was 15.8% among bidet users and 16.0% among nonusers.

Incidence was 9.8% for late preterm birth and 6.0% for early preterm birth.

No association between bidet toilet use and the incidence of preterm birth (adjusted OR 1.04, 95% confidence interval [Cl] 0.72 — 1.48).

Page 13 of 19

Level & Quality of evidence

MODERATE

Big sample, however, retrospective surveys lack reliabilities due to recall bias. Not generalizable to greater female population.

Normal use of bidet toilets by pregnant women does not pose any clinical health risk with regard to preterm birth.

Table 1. Literature Review

Author Aim/Objective

To evaluate the association of bidet toilet use with abnormal vaginal microbial colonization and preterm birth (PTB) in high-risk pregnancies.

Kim, Kim [8]

Research — Adverse effects of bidet use

FOI 25/26-0555

Methods

Analysis focused on those who had a microbiological screening test conducted at approximately 35 weeks.

Bidet toilet use before and during pregnancy, was collected by a self-report questionnaire.

Primary outcome of this study was the incidence of preterm birth. Preterm birth, delivery before 33 weeks of gestation was defined as early preterm birth. Secondary outcome was bacterial vaginosis estimated by the balance of lactobacilli and non- lactobacillus microbes.

Prospective Cohort Study

Pregnant women, who were hospitalized in high-risk units from April 2015 to July 2017, in two tertiary hospitals in Seoul, South Korea were recruited.

Cases with delivery due to

maternal foetal indications (N = 4) were excluded.

22 of 112

Results

No association was observed between bidet toilet use and bacterial vaginosis (adjusted OR 0.96, 95% Cl 0.70—1.33).

No association between bidet toilet use and intestinal bacteria (adjusted OR 0.97, 95% Cl 0.68—1.38) or between bidet toilet use and bacterial vaginosis— related bacteria (adjusted OR 1.00, 95% Cl 0.73- 1.36).

Detection rate of fungi was significantly higher among bidet toilet users (adjusted OR 1.68, 95% Cl 1.14-2.48)

32.8% of the patients responded as users of a bidet toilet.

There were no significant differences in the maternal baseline characteristics, such as the age, the rate of primiparity, and pre pregnancy BMI.

Abnormal vaginal microbial colonization was significantly higher in the bidet user group, compared to the nonuser group (60.7% vs 44.2%, P = 0.036).

Page 14 of 19

Level & Quality of evidence

MODERATE

Prospective, more precise questions asked and swabs used to determine infection rather than recall.

Authors conclude that chronic bidet toilet use, before and during pregnancy, is associated with abnormal vaginal colonization by gram-negative

Table 1. Literature Review

Author Aim/Objective

Implementing bidet in aged care or disability settings

To investigate the feasibility of using a “wash-and-dry” toilet in the nursing home.

Cohen-Mansfield and Biddison [9]

Research — Adverse effects of bidet use

FOI 25/26-0555

Methods

Patients completed a questionnaire which included questions, such as bidet use, purpose of use, duration, mode (feminine mode: cleansing genital lesion, general mode: cleansing anus, or both mode), frequency, time, and strength of the bidet toilet.

Vaginal cultures were taken at the time of admission.

Pseudo randomised trial

Luscence Luxury Lavage toilet

used.

Recruitment focused on female residents who had been identified by nursing staff as having difficulty with cleanliness or toileting care.

Participants randomised to experimental or control group.

15 women received new toilets and were included in the experimental group and 13

23 of 112

Results

This higher rate of abnormal vaginal colonization was attributed to the increased colonization of gram negative bacteria (16.4% vs 6.7%, P = 0.039), especially E. coli (13.1% vs 3.3%, P = 0.023).

Preterm delivery rate of bidet users was significantly higher than that of non-users (87.3% vs 73.0%, P = 0.040).

14 experimental and 8 comparison participants.

27 nursing assistants, of whom 82% were female were interviewed.

8 (57%) of participants in the experimental group had some difficulty in communicating or could not always answer all the questions.

Feasibility

64% (n = 9) of residents were not able to operate the remote control and therefore required staff assistance.

Page 15 of 19

Level & Quality of evidence

bacteria (mostly by E coli) and preterm birth.

LOW

Not completely randomised, small sample, significant drop out rate, self-reported questionnaires used, however, high percentage of participants were unable to provide responses. This severely effects the reliability of the study.

The toilet offered some help with cleaning and drying residents, it was not sufficiently

Table 1. Literature Review

Author

Research — Adverse effects of bidet use

Aim/Objective

FOI 25/26-0555

Methods

women were included in the comparison group

Procedure

Interviews conducted each week with the nursing assistant and residents participating. Following toilet instillation all baseline assessments were repeated each week, an additional toilet reaction scale was administered to the experimental group. Final assessments administered after 2 months.

Qutcome measures

e Resident questionnaires: toileting experience and reaction

e Nursing staff questionnaires: toileting experience Urine test Demographic data

24 of 112

Results

Nursing assistants often not willing to use the bidet as easier to change an adult diaper. 50% (n = 7) of residents were reported to be physically or mentally disabled and consequently difficult to either verbally persuade or physically lift onto the toilet.

Reaction questionnaire Approximately half of staff and residents

responded positively to the use of the bidet.

Logbook entries revealed that residents were rated as clean 49% of the time, as slightly dirty 34% of the time, and in the range from somewhat to very dirty for the remaining 17% of the times that they used the wash-and-dry toilets.

86% of participants in the comparison group versus only 36% in the experimental group had significant bacterial growth in their urine.

Toilet installation was more complex than anticipated.

Page 16 of 19

Level & Quality of evidence

thorough in this regard, and it requires further development.

Table 1. Literature Review

Author Aim/Objective

To study the effectiveness of a modified washing toilet seat equipped with a CCD camera monitor and an electronic bidet to facilitate precise hitting of the anal area with water streams to stimulate bowel movement in patients with spinal cord injury.

Uchikawa, Takahashi [10]

Research — Adverse effects of bidet use

FOI 25/26-0555

Methods

Multiple Case Study Design

Washing toilet seat equipped with an electronic bidet, a CCD camera and a light.

All participants had traumatic SCI.

All patients were at least 5 months post-acute injury and could independently transfer to the toilet seat and change their position on it while watching the CCD monitor.

The maximum duration of stimulation was set at 30 mins, and the maximum power of the water stream was used.

After 30 mins, the amount of residual stool in the rectum was examined using digital evacuation.

25 of 112

Results

20 patients, all males, mean age was 46.3 years (SD 17.9, range 18-73).

The level of injury was cervical in 11 patients, thoracic in 7 patients, and lumber in 2 patients.

Fourteen of the 20 patients (70%) could not direct the water stream precisely to the anorectal area without the use of the monitor.

Bowel movement was successfully induced with the modified device within 30 mins [average time 17mins (range 3— 28)] in 75% of patients.

Time needed for bowel management with the modified device was shorter than that with patients’ usual manner of bowel care (P 0.01).

Time required for successful bowel movement was shortened in 11 of 13 patients (85%) who had spent more than 30 mins with their usual manner of bowel management. However, residual stools were found in 8 of the 15 patients.

Page 17 of 19

Level & Quality of evidence LOW Small sample, no control group. No complications were observed, however, further

research is needed to confirm positive results.

FOI 25/26-0555

7 References

  1. Asakura K, Nakano M, Omae K. Relationship between bidet toilet use and haemorrhoids and
    

urogenital infections: a 3-year follow-up web survey. Epidemiology and infection [Internet]. 2018; 146(6):[763-70 pp.]. Available from: doi:10.1017/S0950268818000584. 2. Kiuchi T, Asakura K, Nakano M, Omae K. Bidet toilet use and incidence of hemorrhoids or urogenital infections: A one-year follow-up web survey. Preventive medicine reports [Internet]. 2017; 6:[121-5 pp.]. Available from: https://dx.doi.org/10.1016/j.pmedr.2017.02.008. 3. Tsunoda A, Takahashi T, Arika K, Kubo S, Tokita T, Kameda S. Survey of electric bidet toilet use among community dwelling Japanese people and correlates for an itch on the anus. Environmental health and preventive medicine [Internet]. 2016; 21(6):[547-53 pp.]. Available from: https://doi.org/10.1007/s12199-016-0578-3. 4. Iyo T, Asakura K, Nakano M, Yamada M, Omae K. Bidet toilet seats with warm-water tanks: residual chlorine, microbial community, and structural analyses. Journal of water and health [Internet]. 2016; 14(1):[68-80 pp.]. Available from: https://dx.doi.org/10.2166/wh.2015.057. 5. Kanayama Katsuse A, Takahashi H, Yoshizawa S, Tateda K, Nakanishi Y, Kaneko A, et al. Public health and healthcare-associated risk of electric, warm-water bidet toilets. The Journal of hospital infection [Internet]. 2017; 97(3):[296-300 pp.]. Available from: https://dx.doi.org/10.1016/j.jhin.2017.07.021. 6. Tsunoda A, Otsuka Y, Toguchi A, Watanabe K, Nishino R, Takahashi T. Survey on bacterial contamination of bidet toilets and relation to the interval of scrubbing these units. Journal of water and health [Internet]. 2019; 17(6):[863-9 pp.]. Available from: https://dx.doi.org/10.2166/wh.2019.234. 7. Asakura K, Nakano M, Yamada M, Takahashi K, Sueoka K, Omae K. Effect of bidet toilet use on preterm birth and vaginal flora in pregnant women. Obstetrics and gynecology [Internet]. 2013; 121(6):[1187-94 pp.]. Available from: https://dx.doi.org/10.1097/AOG.0b013e318291bc16. 8. Kim Y-M, Kim JY, Lee M-Y, Choi S-J, Oh S-Y, Shim J-Y, et al. Prospective study of bidet toilet use: Association of abnormal vaginal colonization and preterm birth in high-risk pregnant women. The journal of obstetrics and gynaecology research [Internet]. 2019; 45(6):[1134-42 pp.]. Available from: https://dx.doi.org/10.1111/jog.13953. 9. Cohen-Mansfield J, Biddison JR. The potential of wash-and-dry toilets to improve the toileting experience for nursing home residents. The Gerontologist [Internet]. 2005; 45(5):[694-9 pp.]. Available from: https://doi.org/10.1093/geront/45.5.694. 10. Uchikawa K, Takahashi H, Deguchi G, Liu M. A Washing Toilet Seat with a CCD Camera Monitor to Stimulate Bowel Movement in Patients with Spinal Cord Injury. American Journal of Physical Medicine & Rehabilitation [Internet]. 2007; 86(3). Available from: https://journals.lww.com/ajpmr/Fulltext/2007/03000/A Washing Toilet Seat with a CCD Camera Monitor to.6.aspx. 11. Garg P. Water stream in a bidet-toilet as a cause of anterior fissure-in-ano: a preliminary report. Colorectal disease : the official journal of the Association of Coloproctology of Great Britain and Ireland [Internet]. 2010; 12(6):[601-2 pp.]. Available from: https://dx.doi.org/10.1111/j.1463- 1318.2009.01867.x. 12. Miura T, Kimura K, Sato Y, Kanai N. Rectal mucosal prolapse syndrome and a bidet. Pediatrics international : official journal of the Japan Pediatric Society [Internet]. 2003; 45(4):[467-8 pp.]. Available from: https://ci.nii.ac.jp/naid/10011918291/. 13. Ogino M, Iino K, Minoura S. Habitual use of warm-water cleaning toilets is related to the aggravation of vaginal microflora. The journal of obstetrics and gynaecology research [Internet]. 2010; 36(5):[1071-4 pp.]. Available from: https://doi.org/10.1111/j.1447-0756.2010.01286.x.

Research – Adverse effects of bidet use Page 18 of 19

26 of 112

FOI 25/26-0555

  1. Shulman O, Wolf Y, Hauben DJ. Perianal burn caused by using the bidet. Burns : journal of the International Society for Burn Injuries [Internet]. 2001; 27(4):[413-4 pp.]. Available from: https://doi.org/10.1016/S0305-4179(00)00124-8.

Research – Adverse effects of bidet use Page 19 of 19

27 of 112

Comments

Loading comments…

What kind of comment is this?
Add a comment