Effectiveness of standard and specialised smoke alarms to wake children and adults

‹ PrevPage 1 of 21 · Source p. 43Next ›
Comments

DOCUMENT 4

OFFICIAL

For Internal Use Only

Effectiveness of standard and specialised smoke alarms to wake children and adults

The content of this document is OFFICIAL.

Please note:

The research and literature reviews collated by our TAB Research Team are not to be shared external to the Branch. These are for internal TAB use only and are intended to assist our advisors with their reasonable and necessary decision-making. Delegates have access to a wide variety of comprehensive guidance material. If Delegates require further information on access or planning matters they are to call the TAPS line for advice.

The Research Team are unable to ensure that the information listed below provides an accurate & up-to-date snapshot of these matters

Research questions:

What evidence is available on the effectiveness of:

  1. Standard fire/smoke alarms (may need to consider domestic and commercial settings?)

  2. Adaptive fire/smoke alarms (visual and tactile or vibration alarms)

Is there any literature that relates specifically to people with hearing impairments versus those without a hearing impairment?

Is there evidence regarding any age groups that typically be awakening and appropriately responding to fire/smoke alarm independently without assistance from an adult/parent?

Expected cost range for visual and tactile/ vibration alarms (hardwired /battery options)

How could current literature inform advice provided against the R&N criteria?

Date: 4/4/2022

Requestor: Karyn Mredacted: s22(1)(a)(ii) - irrelevant

Endorsed by (EL1 or above): N/A

Researcher: Stephanie Predacted: s22(1)(a)(ii) - irrelevant

Cleared by: Stephanie Predacted: s22(1)(a)(ii) - irrelevant

V1.0 04-04-2022

Page 1 of 21

OFFICIAL

43 of 112

OFFICIAL

For Internal Use Only

1. Contents

V1.0 04-04-2022

Page 2 of 21

OFFICIAL

44 of 112

OFFICIAL

For Internal Use Only

2. Summary

Smoke alarms have been proven to save lives. For people who are Deaf or Hard of Hearing, there are specialised smoke alarm systems that use strobe light and/or a pillow vibration device to create an alert signal. There is some evidence in the literature that standard and specialised alarm systems do not reliably wake children, placing them at risk in the event of a residential fire if they are not assisted to escape. There is evidence in the literature that smoke alarms with vibration devices are effective in waking adults who are Deaf or Hard of Hearing from a deep sleep, which would increase the likelihood of a safe escape in the event of a residential fire. The literature indicates that strobe lights are much less effective than vibration devices in waking adults.

3. Background

3.1 Types of smoke alarm

The two most common types of smoke alarm in Australia are the ionisation smoke alarm and photoelectric smoke alarm (Fire and Rescue New South Wales (FRNSW), 2017). The Australian standard for smoke alarms, AS 3786:2014 – smoke alarms using scattered light, transmitted light or ionization, encompasses both of these smoke alarm technologies (Standards Australia, 2022). However, some states in Australia are beginning to mandate the use of photoelectric smoke alarms in Australian dwellings – this is covered in the research paper RES 231 Smoke alarm regulations by Australian State.

A standard for sound and pitch of smoke alarms is not specified, however the most used sound in Australian residential smoke alarms is a continuous 3.1 kHz beep (Thomas & Bruck, 2010a). Ionisation and photoelectric smoke alarms are available in 9V replacement battery, long-life lithium battery and hardwired to mains power options.

Most Australian states and territories recommend smoke alarms adapted for the Deaf and Hard of Hearing in their regulations, however these are not mandatory to install – see RES 231 Smoke alarm regulations by Australian State for further information. Alarm kits for the Deaf and Hard of Hearing people include a smoke alarm connected to a strobe light and/or vibrating

V1.0 04-04-2022

Page 3 of 21

OFFICIAL

45 of 112

OFFICIAL

For Internal Use Only

device (Willoughby, 2009). Standards Australia provides requirements for the individual components used in fire warning systems, including visual and vibrating components, for people with hearing impairment – AS 1603.17:2020 (Standards Australia, 2022).

3.2 Characteristics of fires

Fire and Rescue New South Wales (2017) describe two main types of fire: flaming and smouldering. Flaming fires have a visible flame and all combustible surfaces have reached ignition temperature resulting in full room involvement (FRNSW, 2017). A common source of flaming fires is in the kitchen while cooking (Department of Fire and Emergency Services, n.d.). Smouldering fires are slower to develop, lower temperature and flameless (FRNSW, 2017). Overload of electrical appliances or smoking materials such as cigarettes or incense are common causes of a smouldering fire (Department of Fire and Emergency Services, n.d.).

It was found by FRNSW (2017) that ionisation alarms are activated more quickly with flaming fires and photoelectric alarms activate earlier with smouldering fires. As 62.5% of smouldering fires transition to a flaming fire, the FRNSW (2017) recommend dual smoke alarms that have ionisation and photoelectric technology.

3.3 Domestic vs commercial fires

A study by He and Nelson (2007) reflected that while commercial fires generally have a greater potential for loss of life and property, residential dwellings is where most fire fatalities and injuries occur in Australia. It was proposed this may be because commercial building regulations and legislative requirements are more stringent than in residential dwellings. Additionally, commercial buildings typically have a greater egress timeframe (in the tens of minutes) due to higher smoke reservoir, smoke control systems and sprinklers. Whereas residential buildings might only have a few minutes for safe egress and relies on satisfactory conditions for escape routes through hallways or directly via windows (He and Nelson, 2007).

It was also determined that greater communication during evacuation from commercial buildings, either from staff direction or following other people, increases the effectiveness of smoke alarms in a commercial setting (He and Nelson, 2007).

V1.0 04-04-2022

Page 4 of 21

OFFICIAL

46 of 112

OFFICIAL

For Internal Use Only

3.4 Summary of domestic fire statistics in Australia 2003-2017

In a report commissioned by the Australian Government Department of Industry, Innovation and Science, it was found that children between the age of 0-4 years had the greatest number of deaths for any five-year age range during the 2003-2017 period accounting for 7.8% of fatalities (Coates et al, 2019). The age group most at risk of dying in a preventable residential fire was found to be people over 65 years, accounting for 36.4% of fatalities during this period (Coates et al, 2019). Of all fatalities recorded in this period, 61.8% were people with a disability (Coates et al, 2019).

The report found that the most common time for fires was between midnight and 4am when most people are asleep. However, data suggested that fatalities for people with a disability were most often between 8am and 12pm (Coates et al, 2019). It was suggested that the disability contributed to being unable to escape rather than not waking to the smoke alarm, but more research into this data was recommended (Coates et al, 2019).

4. Assessment of Smoke Alarms

4.1 Standard smoke alarm reliability

He and Nelson (2007) described the ability for smoke alarm systems to operate as required and sound quickly after detecting smoke as their reliability, and their ability to wake people from sleep as effectiveness. The FRNSW (2017) report found that ionisation alarms were quicker to alert with a flaming fire, and photoelectric alarms were quicker when the fire was smouldering.

Room of fire origin smoke alarms were found to be most reliable to activate quickly in the presence of smoke (FRNSW, 2017). Smoke alarms located behind a closed door to the room of fire origin were not found to be reliable to activate (FRNSW, 2017), which is relevant in the context of those Australian states and territories that only have mandatory smoke alarms in hallways outside of bedrooms (see RES 231 Smoke alarm regulations by Australian State for further information). Furthermore, when the room of fire origin was located on a second story, ionisation and photoelectric alarms on the lower level were found to activate only 50% of the

V1.0 04-04-2022

Page 5 of 21

OFFICIAL

47 of 112

OFFICIAL

For Internal Use Only

time (Thomas & Bruck, 2010b). For these reasons, Thomas and Bruck determined that the type of smoke alarm installed was less important than where they were installed.

A higher percentage of fires reported to United States fire departments are in homes without smoke alarms (Gilbert, 2021). FRNSW (2017) found a moderate negative relationship between smoke alarms and fatalities (r = - 0.55), suggesting the presence of working smoke alarms reduced the risk of dying in a preventable residential fire. This data is supported by a German study that examined the impact of mandatory smoke alarm installation which found the fire fatality risk was reduced in 12 of 13 states after the regulation was introduced, with 5 of the 12 being statistically significant (Festag, 2021). Additionally, when the German regulations included installing smoke alarms in existing buildings there was a reduced risk of fatality in 6 of 6 states, with 5 of these 6 being statistically significant (Festag, 2021).

4.2 Standard smoke alarm waking effectiveness

A study by Bruck (1999) evaluated the effectiveness of the standard Australian smoke alarm in waking children and adults without a hearing impairment. They tested a smoke alarm level of 60dB at the pillow, which simulated the loss of sound intensity for a hallway alarm, and sounded the alarm for three minutes. All the adults woke within 32 seconds while only 23% of children (6-17 years old) woke to the three-minute alarm; when considering only the 6-15-year-old children the percentage reduced to 14% that woke with the alarm. The effectiveness of the standard Australian smoke alarm to wake adults without hearing impairment has been replicated in studies by Du Bois (2005) and He and Nelson (2007). He and Nelson (2007) also demonstrated that children aged 6-17 are less likely to wake with a standard smoke alarm, with only 32% waking to the standard alarm in their study.

Standard smoke alarms have not been found as effective to wake adults who are Hard of Hearing compared to adults who are not hearing impaired. Du Bois et al (2005) found only 57% of adults with hearing loss between 20-90dB woke to a standard smoke alarm, and Bruck and Thomas (2007) concluded only 56% of adults with hearing loss between 25-70dB in each ear waking to the standard Australian smoke alarm. As expected, the study by Du Bois et al (2005) found that standard smoke alarms did not wake Deaf adults.

V1.0 04-04-2022

Page 6 of 21

OFFICIAL

48 of 112

OFFICIAL

For Internal Use Only

4.3 Vibration and strobe light smoke alarm waking effectiveness

A 1999 study by Underwriters Laboratories, Nortbrook, cited by Smedberg and Ronchi (2021), demonstrated 95% of adults woke to bed shakers with vibration frequency 100 Hz for four minutes. Of the 77 Deaf children, aged between 10 and 19 years old, between 77-100% woke with the stimulus. The effectiveness for children was shown to depend on the age group however the original paper could not be located for further information. Smedberg and Ronchi also noted this study did not control for sleep stage, so data was not collected with respect to whether participants were in a light sleep or deep sleep at the time of waking.

No further studies regarding the effectiveness of smoke alarm vibration devices in waking children were identified, however two studies for the effectiveness of nocturnal enuresis alarms were found. One study by Tobias and McCain (2001) compared the effectiveness of an audio alarm to a vibration device worn on the body for children between 6 and 12 years old. It was found one third of children in each group were either not awakened by the alerting signal or had an undesirable response such as being frightened by the alarm, disorientation, or throwing the alarm away. Another study by Teles and Lordelo (2016), participant ages were not reported, compared the effectiveness of sound, vibration, and code word enuresis alarms through a review of the literature. It was found alarms with code words improved the waking process compared to the other alarm technologies.

Current literature suggests that strobe lights as a stand-alone strategy is not effective in waking adults. A 1995 study by Bowman et al found only 35% of adults without hearing impairment woke with a strobe light when in deep sleep. Du Bois et al (2005) extended this research to evaluate the waking effectiveness of audible, visual and vibrational alarms for adults with and without hearing impairment: 32 participants were Deaf, 45 Hard of Hearing and 34 had no hearing impairment. The strobe light was most effective in waking Deaf participants, with 57% waking, followed by 34% of the Hard of Hearing participants and 32% of adults with no hearing impairment. The continuous bed shakers were effective in waking across all groups, with 93% of Deaf participants waking, 82% of Hard of Hearing participants and 92% of adults with no hearing impairment. Bed shakers that had an intermittent pattern woke 100% of participants in all groups.

Supporting this research, a 2009 study by Thomas and Bruck compared the waking effectiveness of strobe lights, pillow shakers and bed shakers for Hard of Hearing adults

V1.0 04-04-2022

Page 7 of 21

OFFICIAL

49 of 112

OFFICIAL

For Internal Use Only

(mean age 54.4 years, age range 18-77 years). Results showed that the strobe light woke only 25% of participants, while the bed and pillow shakers woke 84% and 80% respectively.

No research that explored the effectiveness of waking children with a strobe light was found.

4.4 Low frequency and voice alarm waking effectiveness

As a result of the ineffectiveness of the standard smoke alarm to wake children and Hard of Hearing adults, research has been conducted to determine whether sounding a different alarm frequency or using spoken phrases would be more effective in awakening these cohorts.

In a study comparing the effectiveness of a voice alarm, low frequency sound pattern and standard Australian (3.1kHz) beeping alarm to wake sleeping children (aged 6-10 years), it was found that the voice alarm woke the children 100% of the time it was presented, the low pitch pattern 96.4% and the standard alarm only 57% of the time (Bruck et al, 2004). Additionally, the voice alarm and low frequency pattern were quicker to rouse the sleeping children than the standard alarm. Of the children who woke to the standard alarm, over 25% of them took up to 3 minutes to wake whereas the two other alarm systems woke the children within one minute (Bruck et al, 2004).

A further study by Smith et al (2020) compared the effectiveness of female voice, male voice and hybrid voice-low frequency tone smoke alarms with the standard Australian smoke alarm in waking children from deep sleep (aged 5-12 years old). Data showed the male voice (85%), female voice (87%) and hybrid voice-low frequency tone alarms (89%) more effective in waking the children than the standard smoke alarm (56%) (Smith et al, 2020). The studies by Bruck et al (2004) and Smith et al (2020) demonstrate a voice alarm and low frequency pattern are statistically similar in waking children from deep sleep, and statistically superior to the standard Australian smoke alarm.

Further highlighting the benefit of voice alarms for children, as discussed in Section 4.3 of this paper, a study evaluating the effectiveness of sound, vibration and code-word nocturnal enuresis alarms found code-word alarms improved the waking process compared to other alarms (Teles & Lordelo, 2016).

The 2009 study by Thomas and Bruck, discussed in Section 4.3, also evaluated the effectiveness of a low frequency 520Hz square wave signal compared to a strobe light, a vibration device and a standard Australian alarm for Hard of Hearing adults. The low frequency

V1.0 04-04-2022

Page 8 of 21

OFFICIAL

50 of 112

OFFICIAL

For Internal Use Only

alarm was the most effective alerting signal, waking 92% of participants when presented at 75dBA and 100% at 95dBA. Therefore they concluded the most effective alert signal to wake a Hard of Hearing adult was a low frequency alarm; the vibration device was second most effective.

4.5 Factors influencing effectiveness of smoke alarms

Overall smoke alarm effectiveness is a combination of their ability to wake dwelling occupants from deep sleep and wake them quickly enough for adequate egress time.

4.5.1 Factors that influence waking

The ability to wake up to a smoke alarm follows several necessary steps (Bowman et al, 1995):

  • The brain receives the stimulus
  • The brain analyses the stimulus
  • If the stimulus is personally significant then impulses are sent to the appropriate brain area to evoke arousal from sleep

It has been theorised that as the prefrontal cortex matures between 12 and 24 years old, which is believed to be the brain area responsible for judgement decision-making including when asleep, the ability of a younger child’s brain to detect an alerting stimulus to wake the child may not have fully developed (Bruck et al, 2004). On the other hand, adults have the ability to continue to monitor the environment while they are asleep which makes sleep alarms more effective in waking them (Bruck et al, 2004).

Additionally, it has been suggested that alarms are less effective for children because they sleep for longer periods and experience more slow wave/deep sleep compared to adults (Bruck et al, 2004; Smith et al, 2020). The amount of slow wave sleep experienced declines as teenagers mature (Agostini & Centofanti, 2021), which is in line with the data that suggests smoke alarms become more effective to wake teenagers as they get older (Bruck, 1999). Children also have a higher auditory threshold than adults (Splaingard et al, 2007), so the average auditory stimulus required to wake a child is greater than that of an adult for each sleep stage (Smith et al, 2020).

V1.0 04-04-2022

Page 9 of 21

OFFICIAL

51 of 112

OFFICIAL

For Internal Use Only

4.5.2 Factors that influence escape

The time it takes for an alarm to be triggered influences the likelihood of escape, which in turn is influenced by the type of fire, location of alarms and location of exits (FRNSW, 2017). Australian states and territories have their own regulations for the location of smoke alarms in residential dwellings – outlined in RES 231 Smoke alarm regulations by Australian State. Thomas and Bruck (2010b) found that the type of smoke alarm used was much less important than where they were installed and that they should be interconnected.

FRNSW (2017) report that children are unlikely to fully awaken from auditory stimulation by smoke alarms. Children experience greater sleep inertia than adults (Splaingard, 2007; Thomas & Bruck, 2010a), which is the impairment of cognitive and motor functioning on waking from deep sleep. Sleep inertia is responsible for the disorientation and confusion on waking (Smith et al, 2022), making it difficult for children to fully rouse and respond appropriately to an alarm. The unreliable awakening reaction of children to an alarm is another factor that influences the escape process (He & Nelson, 2007; Willoughby, 2009). It has been noted that in the event of an alarm some might children freeze with fear or hide (National Fire Protection Association, 2022; Willoughby, 2009) while others become disorientated as noted by Tobias and McCain (2001).

The ability to open windows and doors and navigate smoky corridors is another issue when it comes to escape for children and people with a disability (Tannous & Agho, 2018). Creating and regularly practising a family fire escape plan with different methods of escape will increase the likelihood of occupants escaping from the dwelling (Queensland Fire and Emergency Services, 2022; Tannous & Agho, 2018).

5.1 Brooks

Brooks is an ‘off the shelf’ option for both hardwired and long-life lithium battery photoelectric smoke alarm systems that can integrate with a hardwired strobe light (with battery backup) and vibration pad (Brooks Australia, 2022). The strobe light is designed to be wall mounted and, as it needs to be connected to the vibration pad, the mounting position must be close to the head of the bed (see Figure 1 below).

V1.0 04-04-2022

Page 10 of 21

OFFICIAL

52 of 112

OFFICIAL

For Internal Use Only

Additional smoke alarms and strobe lights can be connected in living areas for daytime use. The price of one photoelectric smoke alarm, one strobe light and one vibrating pad ranges from $663 (hardwired smoke alarm) to $775.20 (lithium battery smoke alarm) plus electrician fees for hardwire installation. The price breakdown is as follows (Brooks Australia, 2022):

  • Photoelectric hardwired smoke alarm with battery backup $117.70, or
  • Photoelectric RadioLINK long-life lithium battery smoke alarm $229.90, and
  • Strobe with vibration pad $545.30

The Queensland Government smoke alarm subsidy for Deaf and Hard of Hearing people supply the Brooks system (Deaf Connect, n.d.).

Figure 1

Installation of Brooks smoke alarm, strobe light and pillow vibrator

(Brooks Australia, 2018)

5.2 Bellman Visit Smoke Alarm pack

The Bellman Visit Smoke Alarm pack is an ‘off the shelf’ alerting system for Deaf and Hard of Hearing people. The package retails for approximately $629 (Expression Australia, 2022) and includes one photoelectric smoke alarm powered by 9V lithium battery, one strobe light that includes mains adaptor and battery backup and one bed shaker to place under the pillow or mattress - the strobe light connects to the bed shaker. When the smoke alarm is activated it sends a radio signal to the strobe light which in turn activates the bed shaker (Expression Australia, 2022a).

Additional smoke alarms can be connected to the system. Further technology, such as doorbell kits and pager receivers, can also be added to the home alert system (Expression Australia, 2022a).

V1.0 04-04-2022

Page 11 of 21

OFFICIAL

53 of 112

OFFICIAL

For Internal Use Only

An advantage of this system is that installation does not need to be done by an electrician and individual components can be replaced easily in the event of damage to the item.

The Victorian Smoke Alarm Subsidy scheme for the Deaf and Hard of Hearing people supplies the Bellman smoke alarm package (Expression Australia, 2022b).

(Expression Australia, 2022a)

5.3 Visualert

Visualert is a customisable alert system that is provided after consultation with the provider Assistive Tech Suppliers. There is limited information about Visualert systems on their website as enquiries are directed through a quote process. One system is highlighted on the website, The U-Fire Panel, which is hardwired and includes: 5 red LED cornice lights, 1 bed shaker and 2 smoke detectors. Pricing is not available on the Visualert website (Visualert™ U-Fire Panel | Visualert).

Pricing information for a Visualert system was obtained from a TAB advice dated 14/02/2022, which totalled $7483.91 (quote provided in Section 7 of this paper). The package included one Visualert ‘starter system’, one doorbell with sound, one additional smoke detector, and postage and handling. Electrician installation was not included in this price, a further quote for electrical installation was included for $2992.00. The electrician’s quote was for installation of 1 video intercom, 2 smoke detectors, 5 corner flashing LED lights, 1 bed vibrator and 1 light vibration muting button.

Although the literature does not support strobe lights as an effective mechanism to wake sleeping adults, strobe lights in each corner of the room may increase the probability of providing a strobe light alarm with sufficient brightness to wake the room occupant. However there is no evidence in the literature to support increasing the number of lights is more

V1.0 04-04-2022

Page 12 of 21

OFFICIAL

54 of 112

OFFICIAL

For Internal Use Only

effective. A disadvantage of this system could be that people renting might not be able to install all the necessary hardwired components in their dwelling.

5.4 Google Nest Protect Smoke Alarm

Google Nest Protect is an ‘off the shelf’ item with hardwired and long-life lithium battery options. It uses advanced photoelectric technology to sense smoke then send an alarm signal to a phone or tablet (iOS or android). The Google Nest Protect also senses carbon monoxide levels in the home. The Google Nest is designed to give an early warning that there is smoke or increased carbon monoxide levels detected by giving a voice warning and also sending a message to the mobile device. If smoke or carbon monoxide levels become critical, Google Nest Protect will sound the alarm, pulse red and voice where the emergency is as well as send an emergency notification to the mobile device. The smoke alarm can also be set so a ‘Pathlight’ can be activated to help leave the dwelling. The device has a 10-year warranty.

Potential disadvantages of this system are that it relies on a charged functioning mobile phone and WI-FI network. Advantages are this system provides escape instructions by voice and phone message – which may be beneficial after waking and overcoming sleep inertia. Also, notifications can be received by mobile phone while out of the house meaning fire services can be contacted quickly in the event someone is known to be home.

Google Nest Protect Smoke Alarm (hardwired and battery) $189

(JB Hi-Fi, 2022)

6. Reasonable and necessary

Reasonable and Necessary assessment as guided by the literature has been conducted by age group to reflect the differing needs and abilities of these cohorts.

V1.0 04-04-2022

Page 13 of 21

OFFICIAL

55 of 112

OFFICIAL

For Internal Use Only

6.1 Ages 0-4 years

Children under five years old represent the greatest number of fatalities from preventable residential fires of any other 5-year age range (Coates et al, 2019). This age group are dependent on their parents and cannot be expected to open windows or doors to safely evacuate on their own (Smith et al, 2020; Willoughby, 2009). Additionally, children under 5 are at risk of being disorientated, freezing or hiding after being woken by an alarm (FRNSW, 2017). There is no supporting evidence in the literature that providing a specialised smoke alarm system would improve the outcome for this age group in the event of a residential fire. Therefore, funding specialised smoke alarms for this age group would be unlikely to meet Reasonable and Necessary criteria.

6.2 Ages 5-12 years

Children between 5-12 years old have an unreliable waking response (He & Nelson, 2007). This age group have a higher fatality rate in residential fires than teenagers or adults as they are likely to sleep through an alarm (He & Nelson, 2007; Smith et al, 2022).

There was limited literature supporting vibrational devices waking 77-100% of children between 10-17 years old, however the original 1991 paper could not be sourced for further analysis of the data. No literature was discovered in relation to the effectiveness of strobe lights waking children from deep sleep.

When children do wake from deep sleep by an alarm, studies have shown some children in this age range have an undesirable response such as being disorientated, afraid and therefore hiding which increases their risk of perishing in the fire, or throwing the alarm (FRNSW, 2017; Splaingard et al, 2007; Tobias & McCain, 2001; Willoughby, 2009).

Successful self-escape from a residential fire relies on the ability to recall an escape plan, open doors and windows and navigate smoky corridors to make an escape (Tannous & Agho, 2018). Due to the unreliable waking response of this age group, as noted above, this cohort is still reliant on support to escape in the event of a fire. Ultimately, it was concluded by Willoughby (2009), that it is the parents’ or carers’ responsibility to safely support this age group to evacuate. Therefore, providing specialised smoke alarm systems for this age group is unlikely to meet reasonable and necessary criteria.

V1.0 04-04-2022

Page 14 of 21

OFFICIAL

56 of 112

OFFICIAL

For Internal Use Only

6.3 Ages 13-17 years

While some researchers have concluded that children over 13 years can respond well in an emergency (Smith et al, 2020; Willoughby, 2009), it still needs to be considered on an individual basis whether a child has the physical, emotional and cognitive capacity to initiate self-rescue when woken by a specialised smoke alarm. Successful escape from a residential fire depends on their ability to recall their escape plan and ability to open doors, windows and navigate smoky corridors to make their escape (Tannous & Agho, 2018).

Current literature notes the unpredictability of children under 17 years old to wake up from deep sleep by an alarm (Bruck, 1999; He and Nelson, 2007), therefore it would be reasonable to trial a smoke alarm system to ensure the child between 13-17 years can consistently be woken by a specialised smoke alarm. The Bellman Visit Smoke Alarm pack and Brooks smoke alarm systems are the most cost-effective options to trial the effectiveness of a specialised smoke alarm system for children in this age group.

6.4 18+ / Adult

Residential smoke alarms have been proven to save lives. The typical residential smoke alarm emits a high frequency signal that has been shown to be ineffective in waking Deaf or Hard of Hearing people (Du Bois et al, 2005). Therefore, it is reasonable and necessary to provide Deaf or Hard of Hearing adults with a specialised smoke alarm system.

There is some evidence that strobe lights wake Deaf people, however they have been shown to be less effective for Hard of Hearing people (Du Bois et al, 2005; Thomas and Bruck, 2009). Vibrational devices have been shown to be more effective in waking Hard of Hearing people from deep sleep (Du Bois et al, 2005; Thomas and Bruck, 2009).

Some of the common specialised smoke alarms available have been discussed in Section 5. The Bellman Visit Smoke Alarm pack is the system provided by the Victorian Government subsidy scheme while the Queensland subsidy scheme provides a Brooks smoke detector, flashing strobe light and vibration pad (Deaf Connect, n.d.; Expression Australia, 2022b).

The commercial price of the lithium battery operated Bellman and Brooks systems are $629 and $775 respectively, and both systems provide a photoelectric smoke alarm, strobe light and vibrating device.

V1.0 04-04-2022

Page 15 of 21

OFFICIAL

57 of 112

OFFICIAL

For Internal Use Only

The Visualert system must be hardwired and, as per the obtained quote, has more components in the package, including a video intercom. There is no evidence in the literature demonstrating a video intercom improves the effectiveness of a residential smoke alarm system. The Visualert system provides a greater number of strobe lights to place in the corner of the room, however there is no evidence in the literature to show that a greater number of lights will result in waking from deep sleep. The Visualert system is custom designed for each purchaser so a set price is unable to be determined, however the provided quote was almost $7,500. It is unlikely this system would meet reasonable and necessary criteria given there are more cost-effective options available, and these other options are considered suitable and utilised by state government subsidy schemes.

A newer option available commercially is the Google Nest Protect smoke alarm. While this alarm may not be suitable for adults who are Deaf or experience severe hearing loss, it may be beneficial for adults with high frequency hearing loss but can still hear the spoken evacuation instructions that are sounded by the alarm. This is a simpler system than the Bellman or Brooks systems, incorporating only a smoke alarm and a downloaded app onto a mobile device. The smoke alarm itself changes colour when alerting and activates the mobile device. For people who sleep with a mobile device in their bedroom, this may be a sufficient warning system for the detection of smoke or carbon monoxide.

V1.0 04-04-2022

Page 16 of 21

OFFICIAL

58 of 112

OFFICIAL

For Internal Use Only

7. Visualert quote

  • Quote (09/11/2021) from Visualert™ for:
    • 1 x Visualert™ Starter System - $5998.80
    • 1 x doorbell with sound - $245
    • 1 x additional smoke detector - $134.75
    • Postage and Handling - $425
    • GST - $680.36
      • TOTAL=$7483.91
  • Quote from Beal Electrical for:
    • Wire and install Visualert system as per plan
      • 1 x video intercom
      • 2 x smoke detectors
      • 5 x corner flashing LED lights
      • 1 x bed vibrator
      • 1 x light vibration muting button TOTAL: $2992.00

V1.0 04-04-2022

Page 17 of 21

OFFICIAL

59 of 112

OFFICIAL

For Internal Use Only

8. References

Agostini, A., & Centofanti, S. (2021) Normal sleep in children and adolescence. Child and Adolescent Psychiatric Clinics of North America, 30(1), 1-14. http://dx.doi.org/10.1016/j.chc.2020.08.011

Bowman, S. K., Jamieson, D. G., & Ogilvie, R. D. (1995). Waking effectiveness of visual alerting signals. Journal of rehabilitation research and Development, 32(1), 43-45. PMID: 7760267.

Brooks Australia. (2022). Home smoke alarms. Available from https://www.brooks.com.au/home-smoke-alarms/

Brooks Australia. (2018) Deaf & Hearing Impaired RadioLINK Alarm System. Available from https://www.brooks.com.au/index.cfm/_api/render/file/?method=inline&fileID=EDDAD047-4DBA-4A45-AF31FCAA98564B83

Bruck, D. (1999). Non-awakening in children in response to a smoke detector alarm. Fire Safety Journal, 32(4), 369-376. https://doi.org/10.1016/S0379-7112(98)00035-6

Bruck, D., Reid, S., Kouzma, J., & Ball, M. (2004). The effectiveness of different alarms in waking sleeping children. In Interscience Communications, pp 279-290. The 3rd International Symposium on Human Behaviour in Fire, Belfast, Northern Ireland, London. Available from https://vuir.vu.edu.au/447/1/kids_-_belfast.pdf?msclkid=167428cdb0a611ecac7a8b4f283d37ca

Coates, L., Kaandorp, G., Harris, J., van Leeuwen, J., Avci, A., Evans, J., George, S., Gissing, A., van den Honert, R., & Haynes, K. (2019). Preventable residential fire fatalities in Australia July 2003 to June 2017. Bushfire and Natural Hazards CRC. Available from https://www.bnhcrc.com.au/publications/biblio/bnh-5807?msclkid=8ef233e6b08411ec99f7de8076986451

Deaf Connect. (n.d.). How to install your new smoke alarm [fact sheet]. Available from https://deafconnect.org.au/wp-content/uploads/2022/03/SASS-How-to-install-smoke-alarm-.pdf

Department of Fire and Emergency Services. (n.d.). Types of smoke alarms [fact sheet]. Government of Western Australia. Available from https://www.dfes.wa.gov.au/safetyinformation/fire/fireinthehome/FireintheHomeFactsheets/DFES-Smoke-Alarm-Fact-Sheet1-Types-of-Smoke-Alarms.pdf?msclkid=f4ff8e83b14011ec898b0b3ac98843d5

V1.0 04-04-2022

Page 18 of 21

OFFICIAL

60 of 112

OFFICIAL

For Internal Use Only

Du Bois, J., Ashley, E., Klassen, M., & Roby, R. (2005). Waking effectiveness of audible, visual and vibratory emergency alarms on people of all hearing levels. Available from https://tap.gallaudet.edu/Emergency/Nov05Conference/Papers/Du%20Bois.html

Expression Australia. (2022a). Bellman Visit Smoke Alarm Package. Available from https://shop.expression.com.au/products/bellman-visit-smoke-alarm-pack?msclkid=0d6d6a7bb09811ec9341760fe9e184ee

Expression Australia. (2022b). Smoke alarm subsidy. Available from https://www.expression.com.au/services/smoke-alarm-subsidy#:~:text=The%20Victorian%20smoke%20alarm%20subsidy%20scheme%20is%20a,ensure%20safety%20within%20your%20home%2C%20particularly%20when%20asleep.?msclkid=bed44a07b16211ecb532bb163ed3f879

Festag, S. (2021). Analysis of the effectiveness of the smoke alarm obligation — experiences from practice. Fire Safety Journal, 119. https://doi.org/10.1016/j.firesaf.2020.103263

Fire and Rescue New South Wales. (2017). Smoke alarms in homes: an analysis. Fire research report. New South Wales Government. Available from https://www.fire.nsw.gov.au/gallery/files/pdf/research/Fire%20research%20report%20%20Smoke%20Alarms%20in%20Homes%20An%20Analysis.pdf

Gilbert, S. W. (2021). Estimating smoke alarm effectiveness in homes. Fire Technology, 57, 1497-1516. https://doi.org/10.1007/s10694-020-01072-z

He, Y., & Nelson, D. (2007). A comparative study of effectiveness of smoke alarms in two types of buildings. Journal of Fire Sciences, 26, 415-434.

JB Hi-Fi. (2022). Google Nest Protect Smoke Alarm (Battery). Available from https://www.jbhifi.com.au/products/google-nest-protect-smoke-alarm-battery?msclkid=36af9d0eb09811ecb052b87fb0271064

National Fire Protection Association. (2022). When you hear a smoke alarm, get outside and stay outside. Available from https://www.nfpa.org/Public-Education/Teaching-tools/Learn-not-to-burn/Learn-Not-to-Burn-Preschool-Program/When-you-hear-a-smoke-alarm-get-outside-and-stay-outside

V1.0 04-04-2022

Page 19 of 21

OFFICIAL

61 of 112

OFFICIAL

For Internal Use Only

Queensland Fire and Emergency Services. (2022). Fire escape. Available from https://www.qfes.qld.gov.au/Fire-Escape#Create

Smedberg, E., & Ronchi, E. (2021). Review of alarm technologies for Deaf and Hard of Hearing populations [Report 3238]. Department of Fire Safety Engineering, Lund University, Sweden. Available from https://www.nfpa.org//-/media/Files/News-and-Research/Fire-statistics-and-reports/Detection-and-signaling/RFAlarmsForDeafHOH.ashx

Smith, G. A., Chounthirath, T., & Splaingard, M. (2020). Comparison of the effectiveness of female voice, male voice and hybrid voice-tone smoke alarms for sleeping children. Pediatric Research, 88, 769-775. https://doi.org/10.1038/s41390-020-0838-1

Smith, G. A., Kistamgari, S., Splaingard, M. (2022). Optimizing smoke alarm signals for those at highest risk for residential fire-related death: testing the effectiveness of children’s smoke alarms for sleeping older adults. Fire Technology, 58, 311-326.

Splaingard, M., Hayes, J., & Smith, G. A. (2007). Impairment of reaction time among children awakened during stage 4 sleep. SLEEP, 30(1), 104-108. http://dx.doi.org/10.1093/sleep/30.1.104

Standards Australia. (2022a). Standards catalogue. AS 3786:2014. Available from https://www.standards.org.au/standards-catalogue/sa-snz/building/fp-002/as--3786-colon-2014

Standards Australia. (2022b). Standards catalogue. AS 1603.17:2020. Available from https://www.standards.org.au/standards-catalogue/sa-snz/building/fp-002/as--1603-dot-17-colon-2020

Tannous, W. K., & Agho, K. E. (2018). Factors associated with home fire escape plans in New South Wales: a multinomial analysis of high-risk individuals and New South Wales population. International Journal of Environmental Research and Public Health, 15. https://dx.doi.org/10.3390%2Fijerph15112353

Teles, A., & Lordelo, P. (2016). Alarm for the treatment of enuresis: review of treatment types and treatment efficacy. Journal of Sleep Medicine & Disorders, 3(6). Available from https://www.researchgate.net/profile/Patricia-Lordelo/publication/311100785_Journal_of_Sleep_Medicine_Disorders_Central_Alarm_for_the_Treatment_of_Enuresis_Review_of_Treatment_Types_and_Treatment_Efficac

V1.0 04-04-2022

Page 20 of 21

OFFICIAL

62 of 112

[Reséaretf-Paper] OFFICIAL For Internal Use Only

/links/583d82c208ae61f75dc43e1f/Journal-of-Sleep-Medicine-Disorders-Central- Alarm-for-the-Treatment-of-Enuresis-Review-of-Treatment-Types-and-Treatment-

Efficacy. pdf

Thomas, I., & Bruck, D. (2009). Strobe lights, pillow shakers and bed shakers as smoke alarm signals. Fire Safety Science, 9. http://dx.doi.org/10.3801/IAFSS.FSS.9-415

Thomas, I., & Bruck, D. (2010a). Awakening of sleeping people: a decade of research. Fire Technology, 46, 743-761. https://doi.org/10.1007/s10694-008-0065-5

Thomas. I., & Bruck, D. (2010b). Smoke alarms in dwellings: timely activation and effective

notification [Technical report]. Victoria University, Melbourne.

Tobias, N. E. & McCain, G. C. (2001). A comparison of two enuresis alarms. Urologic Nursing, 21(5), 349-353. PMID: 11998300.

Willoughby, L. (2009). Review of the fire alarm subsidy scheme for Deaf and hard of hearing

Victorians. The Victorian Deaf Society, Melbourne.

9. Version control

Version Amended by Brief Description of Change Status Date
0.1 SJP131 Document creation Draft 1/4/22
1.0 SJP131 Final document Cleared 4/4/22

V1.0 04-04-2022 Page 21 of 21

ORF IPIAL

Comments

Loading comments…

What kind of comment is this?
Add a comment